Pni RM3000 Sensor Suites Uživatelský manuál Strana 18

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 41
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 17
PNI Sensor Corporation Doc #1015673 r08
RM3000 & RM2000 Sensor Suite User Manual July 2012 Page 18 of 41
Dimensions: mm
Full reel is 5000 pcs. Smaller quantities on cut-tape.
Tape & Reel meets ANSI/EIA standard EIA-418
Figure 3-17: 3D MagIC Tape Dimensions
3.6 Soldering
Figure 3-18 and Table 3-6 provide the recommended solder reflow profile and processing
parameters for Geomagnetic Sensor Suite components. After soldering PNI components to a
board, it is possible to wave solder the opposite side of the PCB.
IMPORTANT: PNI sensors require the use of halide-free solder pastes and processes for
reflow and cleaning. Please contact PNI if you would like recommendations.
Zobrazit stránku 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 40 41

Komentáře k této Příručce

Žádné komentáře